Type |
Qty |
Use |
Special |
Connection |
Notes |
|
Digital |
56 |
Ground or +12-+24V |
Optically
coupled |
D01-D55
TB19, TB20 |
Input & common operation selected in
groups of 8 via 2-pin jumpers |
|
Analog |
16 |
0-5V, 0-30V, 4-20mA |
Common
Ground |
A00-A15
TB14 |
Range selection resistors plug in including
250.0 ohm 4-20 mA loop resistor |
Nav
Lights |
4 |
Alarm less than 0.50A |
Common
+12 or +24V |
TB18-4 thru TB18-8 |
|
Anchor
Light |
1 |
Alarm less than 0.50A |
+12 or +24V |
TB18-2, TB18-3 |
|
|
AC Voltage |
2 |
120-N-120 voltage measurement |
Transformer
isolated |
TB10-5 thru TB10-7 |
|
|
AC Current |
2 |
2 x 5A current measurement |
CT isolated |
TB10-1 thru TB10-4 |
|
|
Control power |
2 |
Redundant power supply |
10-30V
transient
protected |
TB11- thru TB11-4 |
Common grounds |
|
Test |
1 |
Communications monitoring |
RS232
compatible |
MON |
|
|
Programming |
1 |
MELabs serial programmer |
|
P1 |
|
|
Outputs |
|
Type |
Qty |
Use |
Special |
Connection |
Notes |
|
Relay coil driver |
1 |
Drive 12 or 24 VDC relay coil |
Horn |
TB17-4 and TB17-5 |
Overload and diode protection |
|
Relay coil driver |
1 |
Drive 12 or 24 VDC relay coil |
Beacon |
TB17-2 and TB17-3 |
Overload and diode protection |
|
Communication |
2 |
RS485 & regulated power |
Protection &
regulation |
TB12-1 thru TB12-5
TB13-1 thru TB13-5 |
|
|
|
|
|
|
|
|
|
+V current limited |
4 |
Transducer power |
Up to 120 mA |
TB16-1 thru TB16-5 |
|
|
+V w/o current limit |
4 |
As required |
Total up to 3A |
TB11-5 thru TB11-8 |
|
|
|
|
|
|
|
|
|
Ethernet |
1 |
Web Server |
10Base-T |
RJ1 |
|