Boat Alarm System - Tugboat Alarm System - Ship Alarm System
Skip Navigation Links
Home
Products Expand Products
Testimonials Expand Testimonials
Support Expand Support
Company Expand Company
Web Links Expand Web Links
State of the Art Boat Alarm System, Tugboat Alarm System, Ship Alarm System
DAU - 94 Controller Specifications
Type Qty Use Special Connection Notes
Digital 56 Ground or +12-+24V Optically
coupled
D01-D55
TB19, TB20 
Input & common operation selected in
groups of 8 via 2-pin jumpers
Analog 16 0-5V, 0-30V, 4-20mA Common
Ground
A00-A15
TB14
Range selection resistors plug in including
250.0 ohm 4-20 mA loop resistor
Nav
Lights
4 Alarm less than 0.50A Common
+12 or +24V
TB18-4 thru TB18-8  
Anchor
Light
1 Alarm less than 0.50A +12 or +24V TB18-2, TB18-3  
AC Voltage 2 120-N-120 voltage measurement Transformer
isolated
TB10-5 thru TB10-7  
AC Current 2 2 x 5A current measurement CT isolated TB10-1 thru TB10-4  
Control power 2 Redundant power supply 10-30V
transient
protected
TB11- thru TB11-4 Common grounds
Test 1 Communications monitoring RS232
compatible
MON  
Programming 1 MELabs serial programmer   P1  
Outputs
Type Qty Use Special Connection Notes
Relay coil driver 1 Drive 12 or 24 VDC relay coil Horn TB17-4 and TB17-5 Overload and diode protection
Relay coil driver 1 Drive 12 or 24 VDC relay coil Beacon TB17-2 and TB17-3 Overload and diode protection
Communication 2 RS485 & regulated power Protection &
regulation
TB12-1 thru TB12-5
TB13-1 thru TB13-5
 
           
+V current limited 4 Transducer power Up to 120 mA TB16-1 thru TB16-5  
+V w/o current limit 4 As required Total up to 3A TB11-5 thru TB11-8  
           
Ethernet 1 Web Server 10Base-T RJ1